Quadra-Fire CASTILE-CLG Stove User Manual


 
R
R
R
October 11,, 2005
250-6422D
Page 9
Castile Pellet Stove
*L Exception for Horizontal Installations:
USA INSTALLATIONS: A
noncombustible floor protection is
recommended extending beneath the flue pipe when installed
with horizontal venting or under the Top Vent Adapter with
vertical installation.
CANADA INSTALLATIONS: A
noncombustible floor pro-
tection extending beneath the flue pipe is r
equired
with hori-
zontal venting or under the Top Vent Adapter with vertical
installation.
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
C. Hearth Pad Requirements (UL and ULC)
Use a noncombustible floor protector, extending beneath
appliance and to the front, sides and rear as indicated.
Measure front distance “M” from the surface of the glass
door.
Hearth Pad Requirements
Inches Millimeters
K
Sides 2 51
L*
Back 2 51
M
Front 6 152