Quadra-Fire 844-4120 Electric Heater User Manual


 
January 3, 2007
Page 41Quadra-Fire · Topaz · 7009-113E
Symptom Possible Cause Corrective Action
3. (Continued) c. Defective valve. Turn the valve knob to the ON position. Place the ON/OFF switch in the
ON position. Check the millivolt meter at the thermopile terminals. The
millivolt meter should read greater than 125mV. If the reading is accept-
able, and if the burner does not come on, replace the gas valve.
d. Plugged burner
ori ce.
Check the burner ori ce for stoppage. Remove stoppage.
e. Wall switch or
wires are defective.
Follow the corrective action in Symptom and Possible Cause 1.a.
Check the switch and wiring. Replace where defective.
4. Frequent pilot outage
problem.
a. Pilot ame may
be too high or too
low, or blowing
(high), causing safety
pilot to drop out.
Clean and adjust the pilot ame for maximum ame impingement on
thermocouple. Follow lighting instructions carefully.
5. The pilot and main
burner extinguish while
in operation.
a. No LP in tank. Check the LP (propane) tank. Re ll the fuel tank.
b. Inner vent pipe
leaking exhaust
gases back into the
system.
Check for proper vent connection at ue collar and all vent joints.
c. Horizontal vent
improperly pitched.
The horizontal vent cap should slope down only enough to prevent any
water from entering the appliance.
d. Bad thermopile or
thermocouple.
Replace if necessary.
e. Improper vent cap
installation.
Check for proper installation and freedom from debris or blockage.
6. Glass soots. a. Flame impinge-
ment.
Adjust the log set so that the ame does not excessively impinge on it.
Check that logs are placed according to installation instructions.
b. Improper shutter
setting.
Adjust the air shutter at the base of the burner.
c. Debris around
opening at base of
burner.
Inspect the opening at the base of the burner. NO MATERIAL SHOULD
BE PLACED IN THIS OPENING.
7. Flame burns blue
and lifts off burner.
a. Insuf cient
oxygen being sup-
plied.
Ensure that the vent cap is installed properly and free of debris. Ensure
that the vent system joints are tight and have no leaks.
Ensure that no debris has been placed at the base of, or in the area of
the air holes in the center of the base pan beneath the burner.
Ensure that the glass is tightened properly on the appliance, particu-
larly on top corners.