Quadra-Fire 844-4120 Electric Heater User Manual


 
Page 14
January 3, 2007
Quadra-Fire · Topaz · 7009-113E
Step 5.
Place the wall thimble cover over the pipe assembly and
slide the appliance and vent assembly towards the wall,
carefully inserting the vent pipe into the vent termination
cap assembly. It is important that the vent pipe extend into
the vent termination cap a sufficient distance so as to result
in a minimum pipe overlap of 1-1/4 in. (32mm). Secure the
connection between the vent pipe and the vent termination
cap by attaching the two sheet metal strips extending from
the vent termination cap assembly into the outer wall of
FOLD STRAP
HERE
WALL THIMBLE COVER/CEILING
FIRESTOP AS REQUIRED BY
LOCAL JURISDICTION
1/4 in. (6mm)
STRAP
SHEET METAL SCREW
WALL
THIMBLE
Figure 5.9
Burn Risk.
Local codes may require installation of a cap
shield to prevent anything or anyone from
touching the hot cap.
WARNING
WARNING
Do NOT connect a pipe section to a termination cap without
using the telescoping ue section found on the termination cap.
VINYL SIDING
APPLY SEALANT TO ALL
FOUR SIDES
SCREWS
BOLT HORIZONTAL TOP
TO VINYL STANDOFF
SCREWS
VINYL SIDING STANDOFF
WITH SIDING BENEATH
REMOVED
WALL THIMBLE
WALL THIMBLE
COVER
Figure 5.8
8 in.
(203mm)
7 in.
(178mm)
7 in.
(178mm)
6 in.
(152mm)
Figure 5.7
(NOTE: If you are installing termination cap HHW2, the
pipe will be off center on flashing). Ensure that proper
clearances to combustible materials are maintained. If
you are using an approved termination cap other than
HHW2 (part #841-0670) on a building with vinyl siding,
a vinyl siding standoff should be installed between the
termination cap and the exterior wall (Figure 5.8). Follow
manufacturer’s instructions for attaching the vinyl siding
standoff to the horizontal termination cap. The vinyl
siding standoff prevents excessive heat from possibly
melting the vinyl siding material. The vent terminal cap
shall not be recessed into a wall or siding. Remove
siding from the area where the standoff will be located.
Fire Hazard.
Exhaust Fume Risk.
Impaired Performance of Appliance.
WARNING
Ensure vent components are locked together correctly.
Pipe may separate if not properly joined.
Note: The attachment from the vent pipe to the vent
termination cap must be sealed with silicone. Termination
caps shall not be recessed into a wall or siding.
the vent pipe. Use the two sheet metal screws provided to
connect the strips to the pipe section (Figure 5.9).