1
Listing and Code Approvals
A. Appliance Certifi
cation
C. Glass Specifi cations
E. BTU & Effi ciency Specifi cations
This appliance is equipped with 5mm ceramic glass. Replace
glass only
with 5mm ceramic glass. Please contact your
dealer for replacement glass.
NOTE: This installation must conform with local codes.
In the absence of local codes you must comply with the
ASTM E1509-95, ULC S628-93, ULC/ORD-C-1482-
M1990 and (UM) 84-HUD
D. Electrical Rating
115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps
*BTU output will vary, depending on the brand of fuel you
use in
your appliance. Consult your Quadra-Fire dealer
for best results.
NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products,
their specifi
cations and/or price without notice.
MODEL: Castile Pellet Insert
LABORAT
ORY: OMNI Test Laboratories, Inc
REPORT NO. 061-S-42-2
TYPE: Solid Fuel Room Heater/Pellet Fuel
Burning Type Insert
STANDARD: ASTM E1509-95, ULC S628-93 and
ULC/ORD-C1482-M1990 Room
Heater Pellet Fuel Burning Type and
(UM) 84-HUD, Mobile Home Approved
Colorado: Approved 11-15-02
Particulate Emis-
sions Rating:
0.7 grams/hr
*BTU Output: 8,000 - 30,000 / hr
Heating Capacity: up to 1,500 sq. ft. depending
on climate zone
Hopper Capacity: 45 lbs
Fuel: Wood Pellets or Shelled Corn
Shipping Weight: 260 lbs
WARNING! Risk of Fire! Hearth & Home Technologies dis-
claims any responsibility for, and the warranty and agency
listing will be voided by the above actions.
DO NOT:
Install or operate damaged appliance
Modify appliance
Install other than as instructed by Hearth & Home
Technologies
Operate the appliance without fully assembling all
components
Overfi re
Install any component not approved by Hearth &
Home Technologies
Install parts or components not Listed or approved.
Improper installation, adjustment, alteration, service
or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualifi ed
installer, service agency or your dealer.
Quadra-Fire is a registered trademark
of Hearth & Home Technologies.
T
his appliance is approved for mobile home installations
when not installed in a sleeping room and when an outside
combustion air inlet is used.
The structural integrity of the mobile home fl oor, ceiling, and
walls must be maintained.
The appliance must be properly grounded to the frame of
the mobile home and use only Listed pellet vent Class “L”
or “PL” connector pipe.
A Quadra-Fire Outside Air Kit must be installed in a mobile
home installation. You must order the Outside Air Kit sepa-
rately.
B. Mobile Home Approved
Note: The appliance is also approved for installation
into a shop.