Quadra-Fire 4300 WOOD STOVE SERIES Stove User Manual


 
Page 21
250-7061C December 10, 2004
4300 ACT Wood Stove Series
R
NOTE:
These are approximate settings, and will vary with type of wood or chimney draft. Due to altitude and other environmental circumstances, this
operation information is a guideline only. Similar burn rates may be obtained using other settings unique to your situation.
There are many ways to build a fire. The basic principle is to light easily-ignitable tinder or paper, which ignites the fast burning
kindling, which in turn ignites the slow-burning firewood. Here is one method that works well:
1. Place several wads of crushed paper on the firebox floor. Heating the flue with slightly crumpled newspaper before
adding kindling keeps smoke to a minimum.
2. Lay small dry sticks of kindling on top of the paper.
3. Open Start-Up Air Control and Primary Air Control fully.
4. Make sure that no matches or other combustibles are in the immediate area of the stove. Be sure the room is adequately
ventilated and the flue unobstructed.
5. Light the paper in the stove. NEVER light or rekindle stove with kerosene, gasoline, or charcoal lighter fluid; the
results can be fatal.
6. Once the kindling is burning quickly, add several full-length logs 3” (76mm) or 4” (102mm) in diameter. Be careful not
to smother the fire. Stack the pieces of wood carefully: near enough to keep each other hot, but far enough away from
each other to allow adequate air flow between them.
7. When ready to reload the stove, add more logs. Large logs burn slowly, holding a fire longer. Small logs burn fast
and hot, giving quick heat.
8. Adjust the Start-Up Air Control and Primary Air Control; the more you close down the Primary Air Control, the lower and slower
the fire will burn. The more you open the Primary Air Control, the more heat will be produced. The Start-Up Air Control is only
used for the first 5 to 15 minutes.
As long as there are hot coals, repeating steps 7 and 8 will maintain a continuous fire throughout the season.
NOTE: The special high temperature paint that your stove is finished with will cure as your stove heats. You will notice an
odor and perhaps see some vapor rise from the stove surface; this is normal. We recommend that you open a window
until the odor dissipates and paint is cured.
NOTE: Stove should be run full open for 15 minutes a day to keep air passages clean.
WARNING! ALWAYS OPERATE THIS APPLIANCE WITH THE DOOR
CLOSED AND LATCHED EXCEPT DURING START-UP AND RE-
FUELING .
WARNING! DO NOT LEAVE THE FIRE UNATTENDED WHEN THE DOOR
IS UNLATCHED. UNSTABLE FIREWOOD COULD FALL OUT OF THE
FIREBOX CREATING A FIRE HAZARD TO YOUR HOME.
CAUTION: Before lighting your first fire in the stove: 1) Make certain that the baffle is correctly positioned. It
should be resting against the rear support; 2) Follow instructions on page 22 for cleaning plated surfaces, and;
3) Remove all labels from glass front.
BUILDING A FIRE
CAUTION: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start
or “freshen up” a fire in this heater. Keep all such liquids well away from the heater while it is in use.
For maximum operating efficiency with the lowest emissions, follow these operating procedures:
1.
Regardless of desired heat output, when loading stove, burn your stove with both air controls wide open for 5 to 15 minutes.
2.
Regulate burn rate (heat output) by using the Primary Air Control (center under ashcatcher). The Start-Up Air Control (on the
right) is used for initial start-up and reloading.
3. Heat output settings: Following 5 to 15 minutes of burning with controls wide open (see #1 above):
4. Burn dry, well-seasoned wood.
OPERATING INSTRUCTIONS (Cont’d)
IMPORTANT - PLEASE READ BEFORE USING STOVE
WARNING: Do not operate with Start-Up Air
Control in the open position in excess of 15
minutes! Risk of extreme temperatures! Pro
-
longed operation of this stove with the Start-
Up Air Control in the open position may cause
the combustible materials around the stove to
exceed safe temperature limits.
BTU / Hr
Below 10,000
10,000 - 15,000
15,000 - 30,000
Maximum Heat
Start-Up Air Control
Closed after 5 to 15 minutes
Closed after 5 to 15 minutes
Closed after 5 to 15 minutes
Closed after 5 to 15 minutes
*Primary Control
Pull to Stop
1” - 1-1/4” open
1-1/4” - 2-1/2” open
Fully open