Page 8
A chimney inside the house must have at least 2 (50mm) of clearance to the combustible structure. A chimney
outside the house must have at least 1 (25mm) clearance to the combustible structure. Firestops must be
installed in the spaces where the chimney passes through floors and/or ceiling (Figure 5).
The chimney must have a fire clay flue liner (or equivalent) with a minimum thickness of 5/8 (16mm) and
must be installed with refractory mortar. There must be at least ½ (13mm) air space between the flue liner and
the chimney wall (Figure 4). An equivalent liner must be a listed chimney liner system or other approved
material.
FIGURE 4
FIGURE 5
Page 21
1. Remove door from stove and lay on a padded flat surface.
2. Remove glass frame and screws with a Phillips screwdriver (turn screws counterclockwise).
3. Lift glass frame pieces and glass out of the door frame.
4. Lay new glass with fiberglass tape around it into the door frame, making sure the Quadra-Fire logo reads
correctly to the outside.
5. Place glass frame pieces over the fiberglass tape on the edges of the glass. Be sure glass is centered in the
opening (i.e., same space top and bottom, left and right sides).
6. Reinstall screws tight enough to hold glass and frame in place. DO NOT OVERTIGHTEN.
7. Check again for centering of glass in door frame, and give all screws a final tightening.
DOOR HANDLE ASSEMBLY
GLASS REPLACEMENT
LATCH CAM
NOTE:
Spring handle not included in door
handle assembly. When replacing
door handle, either use old spring
handle or order new spring handle
separately.
DOOR CROSS SECTION
FIBERGLASS
TAPE
GLASS
GLASS FRAME
GLASS TAB SCREW
DOOR GASKET ROPE
REPLACE ONLY
WITH CERAMIC
GLASS