14. CONNECTING THE MAINS SUPPLY
Electrical safety of the appliance is only guaranteed by correct earthing, in compliance with the applicable
standards and regulations.
Connect the boiler to a 230V earthed power supply by means of the three-pin cable supplied ensure that the
polarity is correct.
Use a double-pole switch isolator with a contact separation of at least 3mm in both poles.
In case you replace the power supply cable t a HAR H05 VV-F’ 3x0.75mm
2
cable with an 8mm diameter
maximum outer sheath.
The fuse, a fast-acting type rated 2A, is incorporated into the power supply terminals (remove the black fuse
holder to enable inspection and/or replacement).
IMPORTANT: Check that the overall current drawn by accessories connected to the appliance is less than 1
amp. If the value is greater, a relay must be wired between the boiler control circuit board and the accessories
drawing the higher current.