Pitco Frialator L22-303 Water Heater User Manual


 
I8 Water Cooker Computer Service
Pitco P/N PP11375
L22-303 Rev 0 (01/07) 13
7
8
service menu options below, or press the program key three times to return to normal
operation(display shows either [READY], [ACT xxx’F], or [FILLING ]).
4.7.7 Minimum Fill Time Setting:
This setting adjusts the minimum length of time the heat control process in the computer
will wait before applying heat to the vat when the vat is being filled with water. Heat will
be applied to the vat after the computer senses that the vat is full of water and the fill
time counter expires. The sensing of the water level in the vat takes precedence over
the fill time counter. In other words, the computer will ignore this timer if it does not
sense that the vat is full(if the timer expires before the vat is full). The default setting for
this timer is 20 minutes(20:00). The value range for this timer is from 1 – 30 minutes.
With the control display showing [MORE ], press product key 7. The display will
show [FILLmm:ss], where mm:ss is the current minimum fill time setting in
minutes:seconds. Enter the new timer value using product keys 0-9. Press the
program key to save this setting. The display will now show [MORE ]. Continue
on to the remaining more service menu option below, or press the program key three
times to return to normal operation(display shows either [READY], [ACT xxx’F], or
[FILLING ]).
4.7.8 Pilot Flame Sense Timer Adjustment:
This menu option adjusts the timer that is used by the control to detect an absence of a
pilot flame in the appliance during a cold start. During a cold start of the appliance, the
control will expect to sense a pilot flame before this timer times out. If on a cold start, a
pilot flame is not sensed by the control when this timer expires, the control outputs will
be turned OFF(heat will be turned off), and an alarm will sound. The default value for
this timer is 60 seconds. The value range of this setting is 10 – 60
With the control display showing [MORE ], press product key 8. The display will
show [FLAME xx], where xx is the current pilot flame sense timer value in
seconds. Enter the new value using product keys 0-9. Press the program key to
save this setting. The display will now show [MORE ]. Continue on to the other more
service menu options above, or press the program key three times to return to normal
operation(display shows either [READY], [ACT xxx’F], or [FILLING ]).
5.0 Control Alarm Displays:
This control continually monitors the basic overall functions of the appliance. If any
faults are detected, the control will turn all outputs OFF, suspend any cooking functions
that may be in progress and sound an alarm. One of several alarm messages detailed
below will appear on the control display. If one if these alarms occur, turn off the
control(see section 1.2). to reset the alarm.
5.1 Open Probe Alarm:
[PROBE OP]. Open temperature probe detection is standard on all Pitco controls. This
alarm will occur if the temperature probe is detected to be open. All heating and cooking
functions are suspended if this alarm occurs.