Philips TUFFGUARD Series Indoor Furnishings User Manual


 
P
hilipsTuffGuard
H
igh Intensity Discharge
Coated Lamps—Protected Metal Halide
“O” Rated Lamps
Ordering,Electrical andTechnical Data
M
ax.
R
ated Approx.
Product Nom. Pkg. Avg.Life Initial
Number Description Watts Volts Qty. Bulb Base (Hrs)
1
Lumens
2
Availability
2
0214-3 MP175/BU 12PKTG 175 132 12 ED-28 Mogul 10,000 15,000 Stocked
2
0215-0 MP250/BU 12PKTG 250 133 12 ED-28 Mogul 10,000 22,000 Made to Order
21148-2 MP360/BU/EW 6PKTG 360 120 6 ED-37 Mogul 20,000 34,200 Stocked
20216-8 MP400/BU 6PKTG 400 135 6 ED-37 Mogul 20,000 38,000 Stocked
1
)Average lifeunder engineeringdata with lampsturnedoff andrestarted once every12operating hours.
2
)Protective coating mayreduce actuallumensbyup to5%.
Above specifications aresubject to change without notice.
W
ARNINGS:
•Coating canwithstandbulb wall temperatures upto500°F,subjecttothe followingconditions:
1)Lamp mustbe installedandoperatedin ambienttemperature below150°F.
2)Lamp isnotused infixturethat doesnotallow heat dissipation.
•UV radiationemitted from metal halidelamps maydeteriorate thecoatingovertime.
•The coating isnotdesigned tocontainan arc-tuberupture
•Under extremeconditionsglass fragmentsmayescape thecoating
•Lamps must beburnedbaseuponly
•Only protectiveshrouded lampsareresistant tometalhalide non-passivefailure.
RECOMMENDEDWARNINGS,CAUTIONS,AND OPERATING INSTRUCTIONS
ForProtected Metal HalideLamps (BaseUp Operation± 15˚ Unless Noted;
Open or EnclosedFixtures)
R
“WARNING:
Theselamps cancauseseriousskinburn andeye inflammation fromshortwaveultraviolet
radiation ifouterenvelopeof thelampis brokenor punctured.Donotusewhere people will remainfor
morethan afewminutesunless adequateshieldingor othersafetyprecautions are used.Certain lampsthatwill
automaticallyextinguish when theouterenvelopeis brokenor puncturedarecommercially available.”Thislamp
complieswith FDAradiationperformance standard21CFR subchapter J.(USA:21CFR 1040.30Canada:
SOR/DORS/80-381)
Ifthe outerbulbis brokenorpunctured,turnoff atonceand replacethe lamp to avoid possible
injury fromhazardousshortwaveultravioletradiation.Do notscratchthe outerbulbor subject
itto pressureas this couldcause theouterbulb tocrackor shatter.A partialvacuumin the
outerbulb maycause glassto flyifthe envelopeisstruck.
WARNING:Thearc-tubeofmetalhalidelampsaredesignedtooperateunderhighpressureandattemperatures
upto 1000ºCand canunexpectedlyrupturedue tointernal orexternal factorssuchasa ballastfailureor
misapplication.Ifthe arc-tuberupturesforany reason,theouterbulb maybreak andpiecesof extremely hot
glassmight bedischarged intothesurroundingenvironment.Ifsuch arupturewereto happen,
THEREISA RISKOFPERSONAL INJURY,PROPERTYDAMAGE,BURNSANDFIRE.
Theselamps aredesigned toretainallthe glassparticles should anarc tube ruptureoccur.The
followingoperating instructionsarerecommendedto minimizethese occurrences.RELAMP
FIXTURESATORBEFORETHE ENDOFRATEDLIFE.Allowinglampsto operateuntilthey
failis notadvisedand mayincreasethe possibilityof innerarctuberupture.
CAUTION:TO REDUCETHE RISK OF PERSONALINJURY,PROPERTYDAMAGE,BURNSANDFIRE
RESULTINGFROMANARC-TUBERUPTURETHE FOLLOWINGLAMPOPERATINGINSTRUCTIONS
MUSTBE FOLLOWED:
LAMPOPERATINGINSTRUCTIONS:
1.RELAMPFIXTURESATOR BEFORETHEENDOF RATEDLIFE.Allowing lamps tooperateuntil
theyfail isnotadvised andmayincrease the possibilityof innerarctube rupture.
2.Beforelamp installation/replacement,shutpoweroffand allowlamp andfixtureto cool toavoidelectrical
shockand potentialburn hazards.
3.Useonly auxiliaryequipmentmeeting Philips and/orANSIstandards.Usewithinvoltagelimits recommended
byballast manufacturer.
A.Operate lamp onlywithin specified limitsof operation.
B.Fortotalsupply loadreferto ballastmanufacturerselectricaldata.
4.Periodicallyinspectthe outerenvelope.Replace anylamps thatshowscratches,cracks ordamage.
5.Ifa lampbulbsupportisused,besure toinsulatethe supportelectrically toavoidpossible decomposition of
thebulb glass.
6.Protect lampbase,socket andwiringagainst moisture,corrosive atmospheres and excessiveheat.
7.Timeshould beallowedforlamps tostabilizeincolor whenturned onforthefirsttime.Thismay require
severalhoursofoperation,withmore thanonestart.Lampcolor isalsosubject tochangeunder conditions
ofexcess vibrationor shockandcolor appearancemayvarybetweenindividual lamps.
8.Lampsmay require10to 20minutesto re-light ifthereis apowerinterruption.
9.Take careinhandling anddisposingof lamps.If anarctube isbroken,avoidskincontact withanyof thecon-
tentsor fragments.
10Do notusethis lamp:
A.In afixturethatcontains aPulseStartmetal halideballast.
B.Inafixture thatis specificallydesigned forusewith PulseStartmetalhalide lamps.Operation oftheselamps
onPulse StartMetal Halide systemsmay increasethechance ofanouter bulb ruptureand pieces of
extremelyhotglassmightbedischargedintothesurroundingenvironment.Ifsucharuptureweretohappen,
THEREISARISKOF PERSONAL INJURY,PROPERTYDAMAGE,BURNSANDFIRE.
Made to order requires 3 week lead time
(No product returns on made to order lamps)