8.05 Basic position of the machine drive unit
8
.05.01 On machines with PicoDrive and control unit P41 PD2
Switch on the machine.
Call up the parameter input by pressing the "scroll" key.
To switch the function keys to input (LED in the TE key lights up), press the TE key.
By pressing the corresponding +/- keys, select parameter "798" and service level C,
see Chapter Selecting the User Level in the separate Control Panel Instruction Manual.
Select parameter "799" by pressing the corresponding +/- keys.
Check whether the value is set at "2" and alter if necessary.
Switch the machine off and then on again.
Select parameter "800" by pressing the corresponding +/- keys.
Check whether the value is set at "0" (balance wheel turns towards the operator) and alter
if necessary.
Select parameter "802" by pressing the corresponding +/- keys.
Check whether the value is set at "0" (= no reduction ratio) and alter if necessary.
.By pressing the corresponding +/- key, select parameter "700"
Sew a stitch by operating the pedal.
Turn the balance wheel in the sewing direction until the descending needle is level with
the top edge of the needle plate.
Conclude the adjustment of the sewing motor by pressing the "scroll" key
8
.05.02 With drive system MD-4-58-220-CE
Press and hold button and switch on machine
Parameter 176 is displayed.
Call up parameter 181.
Call up input level.
Sew a stitch with the pedal function.
Turn the handwheel in rotational direction until the needle point (approaching from above)
is on the upper edge of the needle plate.
Confi rm entry.
Call up parameter 192.
Call up input level.
Press button D+ to turn function "off".
Press button "S" to exit input.
A
D
AB
S
AB
S
S