Pfaff 1245 Sewing Machine User Manual


 
Adjustment
11 - 10
2
1
4
5
1
6
Fig. 11 - 08
5
7
3
adjustable clamp is touching the needle bar bearing.
Position the hook point at the middle of the needle, taking care to ensure that the needle
is not pressed by needle guard 7.
While ensuring that bevel pinion 5 is not too close, and that the hook does not exhibit too
much play, tighten screws 2.
On machines with automatic thread trimmer -900/56, bring retaining collar 6 to rest on
bevel pinion 5 and tighten screws 3.
Adjust the needle height in accordance with requirement 2 (see also chapter 11.04.04).
Align needle guard 7 in accordance with requirement 3.
Bei der PFAFF 1246 ist nach Veränderung des Nadelabstandes unbedingt die
Verbindungsstange zum Fadenabschneider (siehe auch Kap.11.05.10)
neu zu justieren.