Pentax N-0751M-OD Water Heater User Manual


 
11
Maintain the following clearances to any
opening in any building:
Illustration
*
For Installations in Canada, clearances are as follows: To windows, doors, & gravity air inlets: 900mm (36").
To forced air inlets: 1.8m (6').
0.9m (3')
0.3m (1')
0.3m (1')
0.3m
(1')
Outdoor Clearances to Opening
into Any Building
• 0.3m (1') below, 0.3m (1') horizontally from,
or 0.3m (1') above any door, operable
window, or gravity air inlet into any building.
0.9m (3') above any forced air inlet within
3m (10').
Vent Clearances When Heater is
Installed in a Recess Box
(recess box installation with cover removed)
0.3m (1')
0.9m (3')
0.3m
(1')
0.3m
(1')
[ For N-0751M- OD]
• 0.3m (1') below, 0.3m (1') horizontally from,
or 0.3m (1') above any door, operable
window, or gravity air inlet into any building.
0.9m (3') above any forced air inlet within
3m (10').
07.1.5, 4:34 PMPage 11