Pelco Manual C495M-D (12/96) 5
Figure 2. HB6000/220 Heater/Blower Kit Wiring Diagram (230 VAC)
4.3.2.3 Heater/Blower Wiring
The blower is factory wired to the PCB assembly. Con-
nect the heaters to the PCB assembly as shown in the
respective wiring diagrams (Figure 2, Figure 3, or Fig-
ure 4). Supply AC line voltage (230 VAC, 120 VAC, or
24 VAC) as shown.
4.4 ELECTRICAL CONNECTION
After the cable has been routed, all wire connections
should be made (i.e., video, lens, camera power, heat-
ers).
CAUTION: When a single power source is
used for both the camera and accessories, the
camera power consumption must be taken into
consideration when determining the wire gauge.
Also, make certain that all electrical connec-
tions are done properly and meet electrical
codes.