PB Heat WV Series Boiler User Manual


 
20
Table 7.1: Boiler Ratings
As an ENERGY STAR
®
Partner, PB Heat, LLC has determined that these firing rates meet the ENERGY STAR guidelines for energy efficiency.
Top venting only.
Nozzles for these firing rates not provided as standard equipment. Consult factory for price and availability.
This firing rate can only be achieved with a Riello F-3 burner. See Table 5.3.
1 Burner input based on No. 2 fuel oil with a heating value of 140,000 Btu per gallon.
2 Net I=B=R water ratings based on an allowance of 1.15.
3 Net I=B=R steam ratings based on an allowance of 1.333.
4 Consult factory before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive
piping systems, etc.
5 Heating Capacity and Annual Fuel Utilization Efficiency (AFUE) ratings are based on U.S. Government tests, with 13% CO
2
and –0.02" w.c. draft over fire.
Before purchasing this appliance, read important information about its estimated annual energy consumptions or energy efficiency rating that is available from
your retailer.
6 Chimney Size: 8" x 8" x 15 ft.
BOILER DIMENSIONS & RATINGS
Series WBV/WV
Model
Number
Input
Heating
Capacity
5
,
MBH Net I=B=R Ratings
4
AFUE,
%
GPH¹ MBH Water Steam
Steam,
sqft
Steam,
MBH³
Water,
MBH² Water Steam
WBV-03
0.60
✚✪
84 75 65 87.5
WBV-03
0.85 119 104 103 321 77 90 86.2
84.8
WBV-03 1.05 147 126 124 388 93 110 85.0 83.6
WBV-04
0.95
133 117 102 87.0
WBV-04
1.25 175 151 151 471 113 131 85.4
85.3
WBV-04 1.50 210 180 179 558 134 156 85.1 84.3
WV-05
1.75 245 212 184 85.5
WV-05
1.95 273 235 204 85.0
Water Content,
gal
Minimum
Stack
Draft
Required,
in. W.C.Water Steam
11.75 -0.03
11.75 12.00 -0.04
11.75 12.00 -0.05
14.75 -0.03
14.75 14.87 -0.04
14.75 14.87 -0.05
17.75 -0.05
17.75 -0.06