Panasonic CU-XE9PKUA Air Conditioner User Manual


 
5
2. Specifications
Model
Indoor CS-XE9PKUA
Outdoor CU-XE9PKUA
Performance Test Condition ARI
Power Supply
Phase, Hz Single, 60
V 208 230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW 0.83 2.55 3.51 0.83 2.55 3.51
BTU/h 2800 8700 12000 2800 8700 12000
kcal/h – – – – – –
Running Current A – 2.80 – – 2.50 –
Input Power W 150 540 850 150 540 850
Annual Consumption kWh – – – – – –
EER
W/W 5.53 4.72 4.13 5.53 4.72 4.13
BTU/hW 18.65 16.10 14.10 18.65 16.10 14.10
kcal/hW – – – – – –
Power Factor % – 93 – – 94 –
Indoor Noise (H / L / QLo)
dB-A 42 / 25 / 20 42 / 25 / 20
Power Level dB 58 / – / – 58 / – / –
Outdoor Noise (H / L / QLo)
dB-A 48 / – / – 48 / – / –
Power Level dB 63 / – / – 63 / – / –
Heating
Capacity
kW 0.89 3.51 5.29 0.89 3.51 5.29
BTU/h 3000 12000 18000 3000 12000 18000
kcal/h – – – – – –
Running Current A – 4.50 – – 4.00 –
Input Power W 150 860 1.65k 150 860 1.65k
COP
W/W 5.93 4.08 3.21 5.93 4.08 3.21
BTU/hW 20.00 13.95 10.90 20.00 13.95 10.90
kcal/hW – – – – – –
Power Factor % – 92 – – 93 –
Indoor Noise (H / L / QLo)
dB-A 42 / 29 / 26 42 / 29 / 26
Power Level dB 58 / – / – 58 / – / –
Outdoor Noise (H / L / QLo)
dB-A 48 / – / – 48 / – / –
Power Level dB 63 / – / – 63 / – / –
17°F: Rated Capacity (BTU/h) / I. Power (W) 8000 / 750
5°F: Max. Capacity (BTU/h) 11000
Max Current (A) / Max Input Power (W) 7.8 / 1.71k
Starting Current (A) 4.50
Compressor
Type Hermetic Motor (Rotary)
Motor Type Brushless (4 poles)
Output Power W 700