Panasonic CU-XE9PKUA Air Conditioner User Manual


 
41
12.12.1.9 Rhythmic Temperature Wave Operation
To further maximize the energy saving during ECONAVI or AUTO COMFORT operates at low activity level.
Start condition
o The unit is operates in Cool or Dry mode under ECONAVI or AUTO COMFORT operation, and
o Human activity sensor detects low activity level, and
o Neuro stable zone continuously for 60 minutes.
Stop condition
o Unit is off, or
o ECONAVI or AUTO COMFORT is off, or
o Human activity sensor detects high activity level or absent, or
Control contents
o When all start conditions complied, set temperature will shift accordingly as following: