Panasonic CU-XE12PKUA Air Conditioner User Manual


 
8
Model
Indoor CS-XE12PKUA
Outdoor CU-XE12PKUA
Performance Test Condition ARI
Power Supply
Phase, Hz Single, 60
V 208 230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW 0.83 3.36 4.10 0.83 3.36 4.10
BTU/h 2800 11500 14000 2800 11500 14000
kcal/h – – – – – –
Running Current A – 4.20 – – 3.80 –
Input Power W 150 800 1.05k 150 800 1.05k
Annual Consumption kWh – – – – – –
EER
W/W 5.53 4.20 3.90 5.53 4.20 3.90
BTU/hW 18.65 14.35 13.30 18.65 14.35 13.30
kcal/hW – – – – – –
Power Factor % – 92 – – 92 –
Indoor Noise (H / L / QLo)
dB-A 45 / 28 / 20 45 / 28 / 20
Power Level dB 61 / – / – 61 / – / –
Outdoor Noise (H / L / QLo)
dB-A 49 / – / – 49 / – / –
Power Level dB 64 / – / – 64 / – / –
Heating
Capacity
kW 0.89 4.05 6.72 0.89 4.05 6.72
BTU/h 3000 13800 23000 3000 13800 23000
kcal/h – – – – – –
Running Current A – 5.80 – – 5.20 –
Input Power W 150 1.15k 2.10k 150 1.15k 2.10k
COP
W/W 5.93 3.52 3.20 5.93 3.52 3.20
BTU/hW 20.00 12.00 10.95 20.00 12.00 10.95
kcal/hW – – – – – –
Power Factor % – 95 – – 96 –
Indoor Noise (H / L / QLo)
dB-A 44 / 35 / 32 44 / 35 / 32
Power Level dB 60 / – / – 60 / – / –
Outdoor Noise (H / L / QLo)
dB-A 49 / – / – 49 / – / –
Power Level dB 64 / – / – 64 / – / –
17°F: Rated Capacity (BTU/h) / I. Power (W) 10400 / 1.05k
5°F: Max. Capacity (BTU/h) 12500
Max Current (A) / Max Input Power (W) 9.5 / 2.15k
Starting Current (A) 5.80
Compressor
Type Hermetic Motor (Rotary)
Motor Type Brushless (4 poles)
Output Power W 700