Panasonic CU-XE12PKUA Air Conditioner User Manual


 
7
Model
Indoor CS-XE9PKUA
Outdoor CU-XE9PKUA
Piping
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 9.52 (3/8)
Standard length m (ft) 7.5 (24.6)
Length range (min – max) m (ft) 3 (9.8) ~ 20 (65.6)
I/D & O/D Height different m (ft) 15.0 (49.2)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Length for Additional Gas m (ft) 7.5 (24.6)
Drain Hose
Inner Diameter mm (inch) 16.7 (5/8)
Length mm(inch) 650 (25-5/8)
Indoor Heat
Exchanger
Fin Material Aluminium (Pre Coat)
Fin Type Slit Fin
Row × Stage × FPI 2 × 17 × 21
Size (W × H × L) mm (inch) 636.5 × 357 × 25.4 (25-1/16 × 14-1/16 × 1)
Outdoor
Heat
Exchanger
Fin Material Aluminium / Blue Coated
Fin Type Corrugated Fin
Row × Stage × FPI 2 × 31 × 18
Size (W × H × L) mm (inch) 36.4 × 651 × 854.5:824.5 (1-7/16 × 25-11/16 × 33-11/16:32-15/32)
Air Filter
Material Polypropelene
Type One-touch
Power Supply Outdoor
Power Supply Cord A Nil
Thermostat Electronic Control
Protection Device Electronic Control
Dry Bulb Wet Bulb
Indoor
Operation
Range
Cooling
Maximum °F/°C 89.6/32 73.4/23
Minimum °F/°C 60.8/16 51.8/11
Heating
Maximum °F/°C 86.0/30 –/–
Minimum °F/°C 60.8/16 –/–
Outdoor
Operation
Range
Cooling
Maximum °F/°C 114.8/46 78.8/26
Minimum °F/°C 0.0/-18 –/–
Heating
Maximum °F/°C 75.2/24 64.4/18
Minimum °F/°C 0.0/-18 -2.2/-19
1. Cooling capacities are based on indoor temperature of 80°F (26.7°C) DRY BULB, 67°F (19.4°C) WET BULB and outdoor air temperature of
95°F (35°C) DRY BULB, 75°F (23.8°C) WET BULB.
2. Heating capacities are based on indoor temperature of 70°F (21.1°C) DRY BULB, 60°F (15.6°C) WET BULB and outdoor air temperature of
47°F (8.3°C) DRY BULB, 43°F (6.1°C) WET BULB.
3. 17°F (-8.3°C) Heating Capacity and Input Power measured at 230V, indoor temperature 70°F (21.1°C), outdoor 17/15°F (-8.3/-9.4°C).
4. 5°F (-15°C) Heating Capacity measured at 230V, indoor temperature 70°F (21.1°C), outdoor 5°F (-15°C/-).
5. Specifications are subjected to change without prior notice for further improvement.