Panasonic CS-CE9GKEW Air Conditioner User Manual


 
7
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
Note
Specifications are subject to change without notice for further improvement.
Fan
Type Cross-Flow Fan Propeller Fan
Material ASG20K1 PP
Motor Type Transistor (8-pole) Induction (6-pole)
Input Power W 70
Output Power W 30 30
Fan Speed
Q-Lo (Cool/Heat) rpm 780 / 1090
Lo (Cool/Heat) rpm 920 / 1150
Me (Cool/Heat) rpm 1175 / 1325
Hi (Cool/Heat) rpm 1430 / 1500 830 / —
SHi (Cool/Heat) rpm 1470 / 1540
Heat Exchanger
Fin Material Aluminium (Pre Coat) Aluminium
Fin Type Slit Fin Corrugated Fin
Row x Stage x FPI 2 x 15 x 21 2 x 24 x 17
Size (W x H x L) mm 610 x 315 x 25.4
36.4 x 504 x 713
684
Air Filter
Material Polypropelene
Type One-Touch
Item Unit
Power Source (Phase, Voltage, Cycle)
ø Single
V 230
Hz 50
Input Power W
Cooling; 915 (185 ~ 1180)
Heating; 1260 (175 ~ 1890)
Starting Current A 5.8
Running Current A
Cooling; 4.2
Heating; 5.8
Power Factor %
Cooling; 95
Heating; 95
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection A 8.7
Power Cord
Number of core
Length m
Thermostat Electronic Control
Protection Device Electronic Control
ITEM UNIT INDOOR UNIT OUTDOOR UNIT