3
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
ITEM UNIT INDOOR UNIT OUTDOOR UNIT
Fan
Type Cross-Flow Fan Propeller Fan
Material ASG20K1 PP
Motor Type Transistor (8-pole) Induction (6-pole)
Input Power W — 62
Output Power W 30 25
Fan Speed
Q-Lo (Cool/Heat) rpm 740 / 790 —
Lo (Cool/Heat) rpm 790 / 840 —
Me (Cool/Heat) rpm 1010 / 1070 —
Hi (Cool/Heat) rpm 1230 / 1300 750 / -
SHi (Cool/Heat) rpm 1270 /1340 —
Heat Exchanger
Fin Material Aluminium (Pre Coat) Aluminium
Fin Type Slit Fin Corrugated Fin
Row x Stage x FPI 2 x 15 x 19 2 x 24 x 17
Size (W x H x L) mm 610 x 315 x 25.4
36.4 x 504 x 713
684
Air Filter
Material Polypropelene —
Type One-Touch —
Item Unit
Power Source (Phase, Voltage, Cycle)
ø Single
V 230
Hz 50
Input Power W
Cooling; 480 (170 ~ 590)
Heating; 650 (160 ~ 1020)
Starting Current A 3.1
Running Current A
Cooling; 2.3
Heating; 3.1
Power Factor %
Cooling; 91
Heating; 91
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection A 4.8
Power Cord
Number of core —
Length m —
Thermostat Electronic Control
Protection Device Electronic Control