Panasonic CS-C24KKS Air Conditioner User Manual


 
6
Control Device Capillary tube Capillary tube
Refrigerant Oil cm
3
ATMOS NM56M or SUNISO 4GDID (650) ATMOS M60 or SUNISO 4GDID (1130)
Refrigeration
Cycle
Refrigerant Type g (oz) R22, 1.27k (44.8) R22, 1.61k (56.8)
Height(I/D / O/D) mm (inch) 290 (11-7/16) 750 (29-17/32) 290 (11-7/16) 750 (29-17/32)
Width (I/D / O/D) mm (inch) 1070 (42-5/32) 875 (34-15/32) 1070 (42-5/32) 875 (34-15/32)
Dimension
Depth (I/D / O/D) mm (inch) 235 (9-9/32) 345 (13-19/32) 235 (9-9/32) 345 (13-19/32)
Weight Net (I/D / O/D) kg (lb) 12.0 (26) 48.0 (106) 12.0 (26) 56.0 (123)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 12.70 (1/2) 6.35 (1/4) / 15.88 (5/8)
Standard length m (ft) 5.0 (16.4) 5.0 (16.4)
Length range (min – max) m (ft) 3 (9.8) ~ 25 (82.0) 3 (9.8) ~ 25 (82.0)
I/D & O/D Height different m (ft) 20 (65.6) 20 (65.6)
Additional Gas Amount g/m (oz/ft) 20 (0.2) 30 (0.3)
Piping
Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6)
Inner Diameter mm 16 16
Drain Hose
Length mm 650 650
Fin Material Pre Coat Pre Coat
Fin Type Slit Fin Slit Fin
Row x Stage x
FPI
2 x 15 x 21 2 x 15 x 21
Indoor Heat
Exchanger
Size (W x H x L) mm 810 x 315 x 25.4 810 x 315 x 25.4
Fin Material Blue Coated Blue Coated
Fin Type Slit Fin Slit Fin
Row x Stage x
FPI
2 x 34 x 17 2 x 34 x 17
Outdoor Heat
Exchanger
Size (W x H x L) mm 25.4 x 714 x 826.2:846.2 25.4 x 714 x 826.2:846.2
Material Polypropelene Polypropelene
Air Filter
Type One-touch One-touch
Power Supply Indoor Indoor
Power Supply Cord A 16 20
Thermostat - Mechanical
Protection Device - -
Dry Bulb Wet Bulb Dry Bulb Wet Bulb
Maximum 32 23 32 23
Indoor Operation Range
Minimum 16 11 16 11
Maximum 52 31 52 31
Outdoor Operation Range
Minimum 16 11 16 11
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Specifications are subjected to change without prior notice for further improvement.
3.
Outdoor Dry Bulb temperature can be set up to 55°C with Indoor Dry Bulb temperature is 29°C. When humidity does not exceed 90% and
room temperature is above 21°C.