32
12.4 Indoor Fan Speed Control
• Indoor fan speed can be set using remote control.
12.4.1 Fan Speed Rotation Chart
Fan Speed (rpm)
Speed
CS-C18KKS CS-C24KKS
Shi 1370 1500
Hi 1200 1350
Me 1110 1230
HLo 1080 1190
CLo 1020 1110
Lo- 850 970
SLo 670 750
Qhi 1110 1150
QMe 1020 1050
QLo 930 960
12.4.2 Automatic Fan Speed Control
• When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the
table.
o Fan speed rotates in the range of Hi, Me and Lo-.
o Deodorizing Control will be activated.
SHi Hi Me HLo CLo Lo- SLo Stop
Hi o
Me o
Manual
Lo o
Normal
Auto o o o o
QHi Hi-90
QMe Me-90
Manual
QLo CLo-90
Quiet
Auto Hi-100 Me-100 o o
Manual o
Cooling
Powerful
Auto o
Manual o o
Normal
Auto o o
Manual o o
Soft Dry
Quiet
Auto o o