Oreck 447628 Air Cleaner User Manual


 
16
General Parts Replacement
Motor Removal and Replacement
1. Remove the cabinet top by pressing
down the thumb latch and sliding the
top forward.
2. Remove the cell assembly (see inside
of top for instructions).
3. Remove the stripper by pulling it
to the right and applying pressure to
the bearing wall. Lift the left hand side
of the stripper out of the bearing wall
locator seat and then remove the
stripper.
4. Flip the unit onto its side with the
bearing wall up and release the two
locking tabs for the bearing wall
assembly by using a regular
screwdriver from the bottom. Place
screwdriver blade into the slot on top
of the snap finger locking tab and twist
the blade slightly while pulling on the
bearing plate. Repeat for the second
tab. The bearing wall may now be
removed by moving the blower wheel
and bearing wall away from the cabinet
and lifting the bearing wall off of the
blower wheel.