Oreck 2000 Vacuum Cleaner User Manual


 
6
9000
2000
3000
4000
VIDES DE SÉRIE
SIMPLY AMAZING
GUIDE D’UTILISATION
FRANÇAIS
•IMPORTANT•
CONSERVEZ CE FASCICULE
®
ASPIRA
TEUR VERTICAL
RAPIDE
A
VEC SYST
ÉME DE NETT
OY
AGE
®
Comprend:
Avertissements de sécurité
Garantie
Mode d’emploi
Guide de dépannage
Accessoires
Bulb Replacement
WARNING: Unplug cord from electrical
outlet before servicing.
fig. 23 Remove lamp housing by removing two (2) screws in the top of
the lamp housing. Pull burned out bulb from holder and replace
with new bulb. Use only Oreck replacement parts. Replace
lamp housing by replacing two screws in the top of the lamp
housing.
Stuffing or Blockage
IMPORTANT: On plush and new carpets, stuffing may occur inside the
the intake tube and the lower tube assembly. This is due to excessive
fuzz and loose cuttings in the carpet. Stuffing could occur for the first few
cleanings until all the loose material is removed. Due to the high
efficiency of the cleaner, many older carpets will cause stuffing when the
cleaner is first used on them. If your vacuum cleaner does not pick up
properly, or makes unusual noise and the outer bag does not fluff up or
balloon open, follow these steps:
WARNING: Unplug cord from electrical
outlet before servicing.
fig. 24 Check for blockage at the mouth of the intake opening. If there
is blockage, remove it with long-nose pliers, a screwdriver or
wire coat hanger. If you can not reach the blockage, remove
baseplate (fig. 25).
fig. 26 If the blockage is not at the base, remove lower tube. Unhook
retainer spring, releasing bottom of bag.
Twist lower collar counterclockwise to slide up. Pull tube out of
base.
fig. 27 2000 Series: If set screw is present, loosen set screw in lower
collar.
fig. 28 9000 Series: Pull rubber collar over plastic tabs on fan
housing, press metal button to release tube. Twist lower tube
and pull apart.
fig. 29 Check for blockage. If blockage is in the tube, remove with a
coat hanger.
fig. 30 If tube is not blocked, look into fan housing. Remove debris
with long-nose pliers, a screwdriver or coat hanger.
fig. 31 To reassemble, check O-ring on tube, and replace if damaged.
Vacuum will not operate properly without the tube O-ring. Slide
O-ring to approximately 2" from base of tube. Replace tube by
first lining up slot at base of tube with inner tab inside fan
housing. Then reinsert tube and push down until the tube is
seated. Make sure O-ring is in place against fan housing
opening. Replace and tighten collar until collar locking tabs are
locked in place.
fig. 28 9000 Series: Place tube in fan housing opening, turn tube until
buttons snap into button holes. Slide collars in position, over
plastic tabs on fan housing. Make sure plastic tabs are inserted
in collar holes.
fig. 32 Make sure collar is not cross threaded on housing. Reattach
bag spring
(fig. 26).
fig. 33 Many times blockage occurs due to a full dust bag causing dirt to
back down the air flow system. When that happens,
the
blockage will be at the top of the system, starting in the area
where the dust bag connects to the connector assembly.
NOTE: If the above actions do not correct the problem, contact an
Oreck authorized service center or call the customer service center.
U.S.: 1-800-989-3535 Canada: 1-888-676-7325
ENGLISH