NuTone CV400 Vacuum Cleaner User Manual


 
6. POWER UNIT INSTALLATION
6.1 LOCATING THE POWER UNIT
Locate the power unit away from the general living area in an accessible
location for cleaning and maintenance.
Locate the power unit within 6 feet of a grounded electrical outlet. The power
unit requires a 120 VAC power source.
Do not locate the power unit close to a source of extreme heat (i.e.: water
heater) or in an area with a high ambient temperature (i.e.: attic, furnace room).
Do not locate the power unit where the temperature can drop below 0°C (32°F).
If the power unit is located in a closet or a small utility room, make sure the area
is well-ventilated (i.e.: with door louvers).
NOTE: Refer to NuTone website for information on tubing installation
(www.nutone.com).
6.2 MOUNTING POWER UNIT
1. Carefully remove debris pail from power
unit. Make sure bag is properly installed in
power unit. Remove accessories and
installation kit. Securely reinstall pail.
2. Install the 3-way elbow on the back of the
power unit and press firmly (do not glue
).
Remove the plastic cap from the inlet
opening only if your installation requires the
connection into both inlets.
3. Install mounting bracket on a wall stud within
6 feet of a grounded electrical outlet, at the
distances specified on illustration beside.
Ensure that wall between mounting bracket
and inlet is straight and leveled.
- 6 -
MINIMUM WALL CLEARANCE
DIMENSIONS
TOP VIEW
FRONT VIEW
INLET
CEILING
EXHAUST
FLOOR
INLET
INLET
AD0043A
WALL BRACKET
12" MINIMUM TO CEILING
30"
18" MINIMUM ABOVE FLOOR
50"
12"
14" MIN.
PVC TUBING STRAP
INLET
EXHAUST
AO0034
CAUTION
Make sure to assemble the wall mounting
bracket with the screws directly onto a
wall stud for a solid installation.
3-WAY ELBOW
DO NOT GLUE
REMOVE
PLASTIC CAP
(IF NEED BE)