Lifebreath 300DCS Air Cleaner User Manual


 
19
AIR SENTRY™ Air Quality Sensor
PART NO. 99-109
Connects to RED, GREEN and YELLOW terminals. Use a minimum
of three lead 18 gauge low voltage wire. 100 ft (30 m) maximum
wire length. Only compatible with ControlAir 15 electronics.
A
IR
IR
S
ENTRY
ENT RY
D
IGITAL
IG ITA L
A
IR
IR
Q
UALITY
UA LI TY
S
ENSOR
EN SO R
FAN SPEED
IND
I
CATO
R
FAN S P
EE D IN DI CA
TO R
Digital Electronic Timer (DET)
PART NO. 99-104
Connects to RED, GREEN and YELLOW terminals. Use a mini-
mum of three 18 gauge low voltage wire. Connect up to 8 on 300 ft
(91 m) wire max. Connect up to 5 on 300 ft (91 m) wire if Air Sentry
is used. Mounts ina2x4box. Shown with a ‘decora’ cover plate
(99-107W).
Ventilation Dehumidistat
PART NO. 99-250
Connects to BLACK, RED, GREEN and YELLOW terminals. Use a
minumum of four lead 18 gauge low voltage wire.
*Only compatible with ControlAir 15 electronics.
VENTILATION
DEHUMIDISTAT
Crank Timer
PART NO. 99-101
Connects to RED and ORANGE terminals. Use a two 18 gauge
low voltage wire. Mounts ina2x4box. The crank timer provides a
solution to installing a system where only 2 wires are present for
the timers.
Off
10
20
30
40
50
60
ControlAir 15 Optional Remote Controls
Optional Main Controls
The amount of ventilation required in your home will fluctuate
according to the activity level in the house. Higher activity levels
require more ventilation.
Main controls can be mounted in a central location of the home (i.e.
beside the furnace thermostat) which will provide the user with com-
plete control over their ventilation system from a convenient location.
Optional Timers
Timers should be present when the HRV/ERV is exhausting from
speciific locations i.e bathrooms, laundry rooms. The Digital
Electronic Timer is the best selection, however, the crank timer will
be necessary if only 2 lead low voltage wires are present.
Only one main control can be installed on your
system.
ATTENTION
Dehumidistat Dial
The dehumidistat is used to
reduce high winter humidity
levels. The dehumidistat acti-
vates high speed ventilation
when the indoor humidity level
exceeds selected setting.
Knockout for the Control Pad
The control pad from the HRV/ERV
fits into this knockout giving full func-
tionality and control of the HRV/ERV
from a remote location.
Knockout for the Control Pad
The control pad from the HRV/ERV
fits into this knockout giving full func-
tionality and control of the HRV/ERV
from a remote location.
Status Light
The status light indicates the
increased fan speed when the
Air Quality Sensor reacts to
odors and contaminants. A slow
flashing light indicates low cont-
amination (medium speed
ventilation) while a fast flashing
light indicates high contamina-
tion (high speed ventilation). The
Air Quality Sensor detects gases
such as cigarette smoke and
formaldehyde. The sensitivity
level of the sensor is adjustable.
Touch Pad
The Touch Pad initiates
high speed operation.
20/40/60 Minute Status Lights
The 20/40/60 Minute Status
Lights indicate the time high
speed operation will be activated.
Crank Dial
Rotate the dial for up to 60
minutes high speed operation.