§3.0 PRE-INSTALLATION PROCEDURES
PLEASE READ CAREFULLY. FAILURE TO FOLLOW THESE PROCEDURES CAN RESULT IN
DAMAGE TO YOUR SYSTEM AND VOID YOUR WARRANTY.
§3.1 PACKAGING
Upon delivery, inspect packaging for damage and report it to your carrier at that time. After
unpacking the system, inspect it carefully for signs of damage. All damage claims should be
made to the delivery carrier.
§3.2 OPERATING LIMITATIONS
Nimbus MN-800 TF units are to be used on potable water only. The user must be sure that water
to be treated is both microbiologically safe and non-toxic. Ensure that the operating parameters
outlined in §3.3 are met at the installation site. Items of most importance are TDS, feed water
pressure, flow rate, chlorine level and temperature range. A water analysis is helpful in
determining if any pre-treatment is needed. If your water analysis shows levels of substances in
excess of the maximums stated in §3.3, contact the Nimbus factory for pre-treatment
recommendations.
§3.3 OPERATING PARAMETERS
MODEL NO. MN-800 TF
Membrane Type Thin Film
Feed Pressure 15-100 psi
(1.0 – 5.9 bar)
Maximum Feed Flow Rate 2.75 GPM
Maximum Temperature 122
°
F (50C)
Maximum Chlorine (continuous) 1.0 ppm
Maximum Total Dissolved Solids (TDS) 5,000 ppm
pH Range 4.0 - 11.0
Iron 0.0 ppm
Hydrogen Sulfide 0.0 ppm
Manganese 0.0 ppm
pH Range (optimum rejection) 5.0 - 8.0
Turbidity < 1.0 NTU
Silt Density Index < 5.0 SDI