Napoleon Fireplaces GT8P Indoor Fireplace User Manual


 
9
W415-0619 / A / 08.09.07
MAINTAIN THESE MINIMUM CLEARANCES TO
COMBUSTIBLES:
Fireplace framing - 6” to top
- 0” to stand-offs (rear and sides)
Fireplace nishing - 0”
FIGURE 14
Do NOT use the replace if any part has
been under water. Call a quali ed service
technician IMMEDIATELY to have the
fireplace inspected for damage to the
electrical circuit.
It is necessary to hard wire this replace.
Permanently framing the replace with an
enclosure, requires the replace junction box
to be hardwired.
This replace must be electrically connected
and grounded in accordance with local
codes. In the absence of local codes, use the
current CSA C22.1 CANADIAN ELECTRICAL
CODE in Canada or the ANSI/NFPA 70-1996
NATIONAL ELECTRICAL CODE in the United
States.
ELECTRICAL CONNECTION
HARD WIRING CONNECTION
CLEARANCES TO COMBUSTIBLES
CAUTION
Risk of Electric Shock!
Control and valve
operate with 120v.
FIGURE 15
NAILING TAB INSTALLATION
To install the replace face
ush with the nished surface,
position the framework to
accomodate the thickness of
the nished surface. Use 4
self tapping screws to secure
the nailing tabs to the 2 x 4’s.
Cover the nailing tabs with
your nishing material.