10
W415-0223 / D / 01.12.04
1. Turn off the electrical power and the gas supply to the
fireplace insert.
2. Remove the fire viewing door. Remove the logs.
3. Detach the two screws from the back of the firebox and
remove the panel, as illustrated.
4. Remove the blower access door held on with the re-
maining 8 screws. Replace the blower access door gas-
ket when changing the blower.
FIGURE 21
4. Disconnect the two blower wires. Remove the blower
bracket secured with one wing nut and lock washer.
For thermodisc replacement: Remove the "Z" shaped
mounting bracket secured to the firebox wall to the left of
the blower. Remove the thermodisc from the bracket and
replace.
5. Replace the blower using the existing bracket. Slide the
vibration reducing pad (A) into the clip (C) and up against
the threaded stud (B) at the other end. The blower must be
able to be positioned entirely onto the pad.
Slide the blower into the clip (C). Secure to the threaded
stud using the existing lock washer and wing nut. Ensure
that the blower does not touch the fireplace base or the
firebox.
6. Reconnect the two wires. Holding the replacement gas-
ket in place, reattach the blower access door and panel.
Replace the logs. Re-install the fire viewing door.
7. Turn the gas supply and electricity back on.
Because the blower is thermally activated, when turned
on, it will automatically start approximately 5-15 min-
utes after lighting the fireplace insert and will run for
approximately 30-45 minutes after the fireplace insert
has been turned off. Use of the fan increases the out-
put of heat.
Drywall dust will penetrate into the blower bearings caus-
ing irreparable damage and must be prevented from
coming into contact with the blower or its compartment.
Any damage resulting from this condition is not cov-
ered by the warranty policy.
r
e
d
w
h
i
t
e
b
l
a
c
k
BLOWER
WIRES
FIGURE 24
THERMODISC
BRACKET
ASSEMBLY
FIGURE 26
FIGURE 25
A
B
C
OPTIONAL BLOWER INSTALLATION
FIGURE 22
FIGURE 23
BLOWER ACCESS DOOR