Napoleon Fireplaces fireplaces Indoor Fireplace User Manual


 
9
W415-0319 / E / 01.17.07
Combustible materials may be installed flush with the front
of the fireplace but must not cover any of the black face-
areas of the fireplace. Non-combustible material (brick,
stone or ceramic tile) may protrude in these areas.
It is not necessary to install a hearth extension with this
fireplace system.
When roughing in the fireplace, raise the fireplace to ac-
commodate for the thickness of the finished floor materi-
als, i.e. tile, carpeting, hard wood, which if not planned for
will interfere with the opening of the lower access door and
the installation of many decorative flashing accessories.
Objects placed in front of the fireplace should be
kept a minimum of 48" away from the glass front
faces of the fireplace.
Refer to pages 13-15 for complete instructions regarding
mantle requirements and installations, log placement,
glass door and upper and lower louvre attachments.
Install the base panels as illustrated in steps 1-4 . The
side panel sits
under the bracket tab. Holding the side
panel in position, bend down the tab to secure. [DETAIL 5.]
FIGURES 9a-e
RETAINER
DETAIL 5
STEP 3
STEP 2
STEP 1
STEP 4
STEP 5
FIGURE 10
DRYWALL
4" MIN
DRYWALL
BRICK PANEL INSTALLATION FACING
FINISHING