Installation requires a minimum of 6 1/2" non-combustible facing material at the top of the fi replace. Refer to either Figure 86a or Figure
86b (depending on your installation) to ensure your fi replace has been installed with the proper requirements for this kit.
Whether installing to a fi nished fl oor or a hearth, a 3/8" clearance must be maintained at the bottom of the clean face surround kit. To obtain
this clearance a fi replace riser is required.
When installing to a fi nished fl oor the fi replace riser must create a minimum clearance of 3 3/8" from the fi nished fl oor to the bottom of the
fi replace.