Napco Security Technologies XP-400 Home Security System User Manual


 
Protecting Yourself While at Home
1
Before armin
g
your system, make sure the Green
Ready
li
g
ht is ON. This indicates that all of your
protective zones are secure. If any zones are open, the correspondin
g
Zone li
g
ht will be ON. Secure
those zones before proceedin
g
.
2
Enter your user code. The Green
Ready
li
g
ht will
g
o out, and the red
Armed
li
g
ht will li
g
ht.
3
Before your exit delay expires, press
to bypass any interior zones, deactivating devices such
as motion sensors, and allowing free movement throughout the premises. The Zone light of any
bypassed zones will flash slowly.
Your system may have been programmed for Automatic Interior Bypass , in which case it will
recognize that you have not left the premises and will automatically bypass any interior zones.
Instant Mode
Pressing
followed by
will cancel the Entry delay , activating the “Instant” mode. This is typically
done in the evening when all family members are home for the night. Instant Mode can be activated at any
time after the system has been armed. The Red Armed light will flash rapidly while in the Instant Mode.
Easy Exit
(optional)
Your System may have been programmed to allow Easy Exit, which allows a user to exit the premises
with the system armed. By pressing
followed by , the protection is removed from the Exit/ Entry
zone for 3 minutes. This will allow, for example, an early morning commuter to exit the house in the
morning, without having to disarm and rearm the system, waking the family.
Arming With a System Trouble Present
(the
9 System Light is Lit)
If the XP400 has a system trouble present, the
SYSTEM l
i
g
ht will be lit and the ke
y
pad sounder
pulsin
g
. If
y
ou cannot immediatel
y
clear the s
y
stem trouble, the s
y
stem can still be armed. Simpl
y
press
to view the trouble, press again to reset the trouble and then arm the system.
For more information, refer to page12. Note: System troubles should be repaired as soon as possible.
Arming Your System
7
SYSTEM
READY
ZONE 3
ZONE 1
ZONE 2
ZONE 4
ARMED
Oi220a
page 7
Tuesday, September 16, 1997 08:30