Napco Security Technologies GEM-RP3DGTL Door User Manual


 
DIRECT ADDRESS PROGRAM MODE
This is an extension of the Dealer Program Mode. This method of programming is used in conjunction with the Keypad
Programming Worksheets contained in the control panel programming guide. Refer to these worksheets to identify the
4-digit location (address) of the feature to be programmed. An illustrative example is provided on the next page.
KEYPAD PROGRAMMING OVERVIEW
Direct Address Programming allows you to go directly to the address
locations and change the data entries to customize your control panel
options. Whereas the Easy Menu Program Mode is a simple quick
start guide with limited options, the Direct Address Program Mode is
more flexible allowing you to change all the options.
It consists of multiple address locations with two data entry locations
each (left and right) as shown in the adjacent diagram.
ACCESSING DIRECT ADDRESS PROGRAM MODE
1 Enter the Dealer Security Code (default = 456789) for a new panel or
enter your custom Dealer Program Code if programmed.
2 Press A
3 Press NO (F) repeatedly until function “17“ (Activate Program
Mode) is displayed.
4 Press YES (E) to enter the Dealer Easy Program Mode.
5 Press C to enter the Dealer Address Program Mode.
ENTERING DATA IN THE ADDRESS PROGRAM MODE
1 Press A
2 Enter the 4 digit Address location
3 Enter the 2 digit data
4 Press D to save.
DATA ENTRY
LOCATIONS
LEFT DIGIT RIGHT DIGIT
3 C
ADDRESS
LOCATIONS
0000
0000
TO
4095
HEXADECIMAL DATA:
BLANK (•) = No Options
1 to 9 = Entries 1 to 9
0 = Entry of 10
B to F = Entries 11 to 15
(Direct Entry)
17
INTERIOR
BYPASS FIRE/TBL SYS TBL CHIME
INTERIOR
BYPASS SYS TBL CHIME
FIRE/TBL
EXAMPLE: Program an Alarm Timeout of 30 seconds.
Press A0712 1G4 D
Alarm Timeout location = 0712
30 second timeout = 1E
Address # Data
A
D
Use 0 -9
for digits 0 - 9
Use 1 -9 for digits 1 - 9
BLANK= 0
A/10 = G 0
B = G 1
C = G 2
D = G 3
E = G 4
F = G 5
14