PAGE 16 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
ST-3050D SUB. PUMP/CTRL. BOX — TRANSFORMER WIRING (CB200)
TRANSFORMER 230/460 VOLTAGE SETTINGS
CAUTION:
Transformer 230/460 Voltage Settings:
Pump motors are factory set at 230 VAC. The
transformer (Figure 6) of this control box
must
be set to the voltage requirements of the pump
in use. Refer to the attached wiring diagram
located inside the "Control Box" or reference Figures 7 & 8.
Use the two supplied
jumper tabs
to set the transformer to the
required output voltage.
WARNING:
ALWAYS
make sure that the transformer is set
to the correct output voltage. Incorrect transformer
output voltage settings can cause severe damage
to the pump.
Figure 6. Transformer AC Voltage Settings (Jumper Tabs)
NOTE
Transformer settings
are for CB 200 Control
Box only!