Multiquip cx400 Septic System User Manual


 

SPECIFICATION
1.  – Upon start-up, the pump "kicks" in the opposite direction of motor rotation. The correct rotation is
counterclockwise (CCW) as viewed from the impeller end of the pump.
2.  – Use Paraffin P70 oil lubricant. Fill oil cavity 75% to 85% full (allow air space for expansion).
3.  - For unattended operation use CB3 Control box (Table 2).
Specifications
Model CX400/PX400
Type Submersible Trash Pump
Motor Type Condenser Start Condenser Drive
Impeller Plastic
Suction & Discharge Size 2 in. (50 mm)
Maximum Pumping Capacity 72 gallons/minute/(273 liters/minute)
Max Head 34 ft. (10.3 meters)
Power 1/2 HP (.37 kw)
Voltage Phase 1Ø 115 V
Starting Amps 35.4 18.4
Running Amps 7 6.2
Control Box Required NO (See Note 3)
Temperature Range 32° - 104°F (0° - 40°C)
Thermal Overload Protection YES
Rotation CCW (See Note 1)
Mechanical Seal Oil Capacity
15.54 in
3
(255 cc)
(See Note 2)
10.67 in
3
(175 cc)
(See Note 2)
Power Cable Length 19 ft (approximately 6 m)
Dry Net weight 21.4 lb (9.7 kg) 18.3 lb (8.3 kg)
Table 2. 
Model 



Protection

Capability
CB3 115 VAC, 60 Hz Single Phase YES NO YES