Multiquip cx400 Septic System User Manual


 


1. Connect a 2-inch hose to the discharge port on the
pump as shown in Figure 11. Make sure that hose is
attached correctly to the discharge port.

1. Attach a suitable lifting cable (rope) to the carrying
handle (Figure 11) on the pump and lower the pump
into place. For applications where there is an excessive
amount of mud, grit or silt, the use of a support platform
is desirable. When pumping water from swimming pool
type applications where there is little or no debris, the
support platform is not required.
Figure 11. Submersible Pump
Upright Position (Correct)
2. Make sure the pump is always placed in an upright
position (Figure 11, and not tilted (Figure 12). Never
position the pump directly on a soft, loose bottom.
Remember to attain maximum pumping capacity and
prevent excessive wear. Position the pump so it will
not burrow itself into sand or clay.
LIFTING
ROPE
2-INCH
DISCHARGE
HOSE
SUPPORT
PLATFORM
CARRYING
HANDLE
POWER
CORD
115 VAC
POWER
PLUG
GREEN
BLACK
EXTERNAL
1Ø115V
AC,60Hz
POWER
SOURCE
CIRCUIT
BREAKER
L
N
WHITE
GND.
BUS
SUBMERSIBLE
PUMP
OPERATION
Figure 12. Submersible Pump
Tilted Position (Incorrect)

1. Make sure circuit breaker supplying power to pump
motor is in the  position.
2. Insert the power cable plug (Figure 11) into the
appropriate power source receptable. The correct
source voltage for this pump is 115 VAC, 60 Hz,
single-phase.
3. If all of the pump's electrical requirements have been
met, place the circuit breaker or power ON/OFF switch
in the  position.
4. Wait a few seconds and water should begin to flow
from the discharge hose.
5. If water is not flowing from the discharge hose or not
flowing freely after a few minutes, place the circuit
breaker or ON/OFF switch in the  position and
check the system for leaks.
SUBMERSIBLE
PUMP
NOTICE
When connecting the pump directly to a power source
(no control box), it is recommeded that personnel
monitor the pump while in operation. Severe pump
damge can occur if left unattended.
For unattended operation Multiquip recommends the
use of the CB3 control box.