Monessen Hearth VWF18 Indoor Fireplace User Manual


 
6 27D8520
Height of Restriction (X) Minimum Depth of Fireplace/Firebox
No restriction 13" Manual Control 13
1
/2" Milli-Volt Control
0 to 1.5" 15"
Greater than 1
1
/2" to 3" 15"
Greater than 3" ANY BARRIER GREATER THAN THREE INCHES (3")
PLACED IN FRONT OF THE GAS LOG SET IS NOT
RECOMMENDED BY THE MANUFACTURER.
PLACEMENT IN A FIREPLACE WITH A RESTRICTIVE BARRIER
IMPORTANT INFORMATION FOR THE INSTALLATION OF THIS GAS LOG SET
The following are guidelines for placing a VWF log set in a fireplace that has a restrictive barrier along the bottom front
opening of the fireplace. Some examples of barriers are glass/screen door frames and sunken/recessed fireplaces.
Glass door frames
with adjustable
louvers should have
the lovers fully open
while the unit is in
operation.
Height of restrictive barrier
caused by glass door frames,
recessed replaces, etc. from
the base or bottom surface of the
unit. (Refer to Table).
The log set should be
placed against or as near
as possible to the rear wall
of the replace/ rebox.
Depth of replace/ rebox.
(Refer toTable).
Figure 2
NOTE: Non combustible material such as
refractory brick may be used to line the
oor of the replace in order to raise the
height of the gas log set in relation to a
restrictive barrier.
X
Barriers such as the bottom of a glass door frame placed in front of a gas log set can
change the air ow characteristics of the replace which in turn can cause the unit to
overheat and malfunction. Any deviation from the installation guidelines on this sheet
will potentially void the warranty.
WARNING
If the replace has a restrictive barrier
and is equipped with a remote receiver,
it must be placed outside or the
combustion chamber. See “Installing
Receiver” on page 9.
CAUTION