Monessen Hearth NB18 Electric Heater User Manual


 
6 81D0107
PRODUCT FEATURES AND SPECIFICATIONS
NATURAL GAS
NOTE: An external regulator is required to reduce supply pressure to a maximum of 10
1
/2" W.C. on
natural gas systems operating at higher pressure.
MILLIVOLT
Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Max 10
1
/2" w.c.
Min. 5" w.c.
PROPANE/LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
MILLIVOLT
Regulator Pressure Setting: 10" w.c
Gas Inlet Pressure: Max. 13" w.c.
Min. 11" w.c.
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Millivolt control has four (4) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN - Valve position to light/maintain a standing pilot.
ON - Valve position to turn ON/OFF log set with remote switch/thermostat.
LOW/HI - Variable position to control flame height (heat output).
PILOT/ODS
The gas log heater is fitted with a specially designed safety pilot (ODS assembly) which senses the amount of oxygen avail-
able in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can
only be relit when adequate fresh air is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a Millivolt (thermopile) generator to provide power for remote activation.
Model Number Control
Gas Rate
Max BTU/Hr Min BTU/Hr
NB18NV Millivolt 28,000 19,000
NB24NV Millivolt 37,000 25,000
Model Number Control
Gas Rate
Max BTU/Hr Min BTU/Hr
NB18PV Millivolt 27,000 22,000
NB24PV Millivolt 36,000 28,000