Monessen Hearth IDV490PVC Indoor Fireplace User Manual


 
8
57D0016
IDV380/IDV490 Fireplace Insert


No combustibles (ie: drapes, doors) may be within, or swing within 36" of the front of the insert.





The insert must be installed on a noncombustible hearth extending a minimum of 1" from the
fireplace opening (local codes may require a larger hearth). The hearth must also extend to both
sides of the face.
Figure 4 -
Mantel Clearances
FP2623
Minimum clearances
Max.
13”
Max.
3/4”
Min.
9”
Min.
11”
13” (330 mm)
Maximum Depth
Minimum
11” (279 mm)
Minimum
8” (203 mm)
22”
(559 mm)
Minimum
10” (254 mm)
Minimum 42”
(1067 mm)
Minimum
8” (203 mm)
Minimum
8” (203 mm)
32”
(813 mm)
Minimum
12” (305 mm)
3/4" Maximum
Depth
Combustible
Facing
FP63