57D0016
IDV380/IDV490 Fireplace Insert


The manifold is shipped attached to insert. It may be
removed to allow tight installation. Manifold may be loos-
ened and rotated for desired
pipe location.
1. Remove brick liner and
baffle.
. Remove manifold. Place
manifold in fireplace.
3. Route flex vent through chim-
ney from above. Figure 10.
Leave an extra 3" (914 mm)
at the top.
FP2629
flex vent
Flex
Vent
Chimney
Manifold
Bracket
Nut
FP69
Figure 10 -
Place Manifold into Fireplace
FP2630
attach flex vent
Extra 3"
Chimney
Flex
Vent
Manifold
FP630
Figure 11 -
Attach Flex Vent to Manifold
4. Attach flex vent to
manifold. Figure 11.
Seal with silicone
and attach with
screws.
FP2631
pull excess vent
Excess
Flex
Vent
Chimney
Slack in
Flex Vent
Manifold
FP63
Figure 12 -
Pull on Excess Flex Vent
5. Place mani-
fold in an upright
position. Pull on
excess vent. Figure
12. Temporarily
attach flex vent
to top of chimney.
Leave some extra
slack in flex vent.
FP2632
place insert
Vent
Termination
Chimney
Excess Slack
Take out of Flex
Vent
Manifold
Bracket
Nut
FP63
Figure 13 -
Slide Insert into Place
Insert
6. Slide insert into place.
Guide the manifold
over the insert until it
is fully in place. Figure
13
7. Remove any slack from
flex vent. Attach mani-
fold to insert. Figure
13
8. Remove any excess
slack in flex line. Attach
ve nt te rm in at io n.
Figure 13
9. Replace baffle and
brick liner.