Monessen Hearth BWBC400A Indoor Fireplace User Manual


 
10 61D0006
SCL Telescoping
Chimney Cap
Flat Chase Flashing
R3672 (36"x72")
or
R4884 (48"x84")
Chimney Sections
“S” Series
Insulate Outside
Walls of Chase
Solid Continuos
Surface
Insulation
(Thermal Barrier)
Outside Base
Solid
Surface
8'0"
Level
Joist Insulate
Same as Ceiling
See
Warning
Below
SF Firestop
Spacer
INSTALLATION PREPARATION
• You must use Model SF Firestop
• It is recommended for safety and reducing heat loss that firestopping be used at the
ceiling level for chase installation even if local codes do not require firestopping.
• Do not insulate chase with blown or fill type insulation. Only allow insulation to come
into contact with fireplace at points where fireplace would normally be contacted by
framing materials.
WARNING
Figure 5 - Installing Fireplace on an Outside Wall
LOCATING CHIMNEY (CONTINUED)
If the fireplace is to be installed on an outside wall, the surrounding walls (chase) must be constructed and insulated.
See Figure 5. If you do not insulate the fireplace from outside temperatures, heat loss through and around the fireplace
will occur.