61D1013 7
17"
21
1
/
2
"
BUF400: 35
1
/
2
"
BUF400: 20
3
/
8
"
BUF500: 26
3
/
8
"
BUF500: 41
1
/
2
"
Carefully select the best location for installation of your
vent-free firebox. The following factors should be taken
into consideration:
• Clearance to side wall, ceiling, woodwork and windows.
See “Clearances/Height Requirements on page 8.
Minimum clearances to combustibles
• Location must not be affected by drafts caused by
kitchen exhaust fans, ceiling fans, return air registers
for forced air furnaces / air conditioners, windows or
doors.
• Installation must provide adequate ventilation and
combustion air.
•
• Location should be out of high traffic or windy or drafty
areas.
•
• Never obstruct the front opening of the vent-free firebox or restrict the flow of combustion and ventilation
air.
• Minimize modifications to existing construction. Refer to Figure 3 below for location suggestions.
• Do not install in the vicinity where gasoline or other flammable liquids may be stored. The vent-free firebox
must be kept clear and free from these combustible materials.