Wood can be dried sufficiently for burning within a few weeks if protected form rain in a low humid-
ity area. It is far better to cut wood and allow it to dry for a year. In all cases, the wood should be
stacked so that both ends of the sticks are exposed to the air and protected from rain. The drier
the wood, the more usable heat produced by the fire and less likely rapid accumulation of soot and
creosote within the chimney is to occur. See the section of this manual concerning chimney main-
tenance for information concerning the hazards of soot a creosote accumulation. Small quantities
of wood required for fire tending must be kept at least 30 inches from the fireplace.

Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes
should be placed on a noncombustible floor or on the ground well away from all combustible ma-
terials pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally
dispersed, they should be retained in the closed container until all cinder has thoroughly cooled.
Ashes should never be placed in a container with combustible materials.

Creosote, Formation and Need for Removal: When wood is burned slowly, it produces tar and
other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors
condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue
accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire.
The chimney should be inspected at least twice a year during the heating season to determine if a
creosote buildup has occurred.
If creosote has accumulated it should be removed to reduce the risk of a chimney fire.
The chimney cap can be removed for inspection, maintenance and cleaning by removing three
screws from the support legs and lifting upward.
When the fireplace is first in use, inspect the chimney frequently and clean the chimney any time an
accumulation is observed on the flue walls. The frequency of these inspections can be increased
or reduced appropriately after a pattern of accumulation has been established. Please note, how-
ever, that changes in the outside environmental conditions such as temperature and humidity or
changes in the operation of the fireplace can lead to rapid buildup of soot and/or creosote.
To clean the chimney, obtain the services of a qualified and reputable chimney sweep, or remove
the accumulation with brushes on wooden or fiberglass poles. Do not use metal pipes, chains,
wires, etc., to clean the chimney because such items can scratch the surface of the stainless steel
flue which can shorten the life of the flue and provide a rough surface for soot particles to attach
to.
Be sure to cover nearby furnishing and arrange some method of catching soot and creosote parti-
cles that may fall during the chimney cleaning process. If glass doors are installed on the fireplace,
they should be closed. Extra caution must be used to avoid damage to the flue damper during the
cleaning process.
In addition to checking and cleaning the chimney on a regular basis, be sure to inspect the chimney
before starting a fire at the beginning of each heating season. Make sure the chimney is clear from
any accumulation of soot, creosote or any other debris, and that all joints are intact.
MHSC does not recommend chemical cleaners because some may contain elements that corrode