7
Notes w1 : Rating conditions (cooling) — Indoor : 80˚FDB, 67˚FWB, Outdoor : 95˚FDB, 75˚FWB
Operating Range
ITEM MODELS MS15NN MS17NN
Cooling capacity
Power consumption
EER [SEER]
INDOOR UNIT MODEL
External finish
Power supply
Max. fuse size (time delay)
Min. ampacity
Fan motor
Airflow Lo—Me—Hi
Moisture removal
Sound level Lo-Me-Hi
Cond. drain connection O.D.
Dimensions
Weight
OUTDOOR UNIT
External finish
Power supply
Max. fuse size (time delay)
Min. ampacity
Fan motor
Compressor
Refrigerant control
Sound level
Dimensions
Weight
REMOTE CONTROLLER
Control voltage (by built-in transformer)
REFRIGERANT PIPING
Pipe size
Connection method
Between the indoor
& outdoor units
w1
w1
w1
Dry
Wet
W
D
H
Model
Winding resistance (at 68˚F) ½
W
D
H
Liquid
Gas
Indoor
Outdoor
Height difference
Piping length
Btu/h
W
V, phase, Hz
A
A
F.L.A
CFM
CFM
Pints/h
dB(A)
in.
in.
in.
in.
lbs
V, phase, Hz
A
A
F.L.A
R.L.A
L.R.A
dB(A)
in.
in.
in.
lbs
in.
in.
ft
ft
14,300/14,600
1,370/1,400
10.4/10.4 (10.5/10.5)
MS15NN
0.6
0.43
360-395-452
293-321-367
4.7
36-39-42
MU15NN
14
RH207NHDT
C-R 1.68 C-S 2.78
10
35
52
92
White
115, 1, 60
15
5/8
39-15/16
7-1/2
12-5/8
31
Munsell 5Y6.5/1
208/230, 1, 60
20
0.52
Capillary tube
33-7/16
11-7/16
23-13/16
Wireless type
12V DC
Not supplied (optional parts)
1/4
5/8
Flared
Flared
Max. 25
Max. 49
15,900/16,100
1,570/1,600
10.1/10.1 (10.2/10.2)
MS17NN
0.7
0.51
406-441-491
346-374-417
5.1
40-43-45
MU17NN
15
RH231NHDT
C-R 1.65 C-S 2.67
11
38
52
97
Cooling
Maximum
Minimum
Indoor intake air temperature
95˚FDB, 71˚FWB
67˚FDB, 57˚FWB
Outdoor intake air temperature
115˚FDB
67˚FDB
When MS15NN indoor unit is operating with MUM30NN outdoor unit connected.
(Please refer to the manual No.OB202 for MUM30NN.)
OB192--1.qxp 23/6/97 11:45 PM Page 7