Mitsumi electronic MS15NN (WH) Air Conditioner User Manual


 
23
w1 After the system restarts by the remote controller, the system operates with the previous set temperature regardless of
the initial set temperature.
The set temperature is calculated by the previous set temperature.
(5) TEMPERATURES buttons
In “I FEEL CONTROL” mode, set temperature is decided by the microprocessor based on the room temperature.
In addition, set temperature is controlled by TOO WARM or TOO COOL buttons when you feel too cool or too warm.
Each time the TOO WARM or TOO COOL button is pressed,the indoor unit receives the signal and emits a beep tone.
Fuzzy control
When the TOO COOL or TOO WARM button is pressed, the microprocessor changes the set temperature, considering
the room temperature, the frequency of pressing TOO COOL or TOO WARM button and the user’s preference to heat or
cool. So this is called “Fuzzy control”, and works only in “I FEEL CONTROL” mode.
In DRY mode of “I FEEL CONTROL”, the set temperature doesn’t change.
TOO
COOL
To raise the set temperature 2~4 degrees(°F)
TOO
WARM
To lower the set temperature 2~4 degrees(°F)
(4) The initial set temperature is decided by the initial room temperature.
w 1
COOL mode of
“I FEEL CONTROL”
DRY mode of
“I FEEL CONTROL”
Model
Initial room temperature
79: or more
79˚F or more
55˚F to 77 ˚F
Initial room temperature
minus 4˚F
Initial room temperature
minus 4˚F
Initial set temperature
75˚F
OB192--1.qxp 23/6/97 11:46 PM Page 23