Mitsumi electronic MS15NN (WH) Air Conditioner User Manual


 
16
5. OPERATING RANGE
(1) POWER SUPPLY
Models
MS09NW
MS12NN
MS15NN
MS17NN
MU09NW
MU12NN
MU15NN
MU17NN
Indoor unit
Outdoor unit
Rating
115V 60Hz 1[
208/230V 60Hz 1[
Guaranteed Voltage
Min. 103V — Max. 127V
Min. 198V 208V 230V Max. 253V
6. OUTLET AIR SPEED AND COVERAGE RANGE
Model
MS09NW
MS12NN
MS15NN
MS17NN
Function
Dry
Wet
Dry
Wet
Dry
Wet
Dry
Wet
328
279
452
392
452
367
491
417
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
25.6
21.8
29.2
25.5
29.2
23.9
31.7
27.0
Air flow
(CFM)
Air speed
(ft/sec.)
Coverage
range (ft)
7. ADDITIONAL REFRIGERANT CHARGE (R-22(oz))
Model
MS09NW
MU09NW
MS12NN
MU12NN
MS15NN
MU15NN
MS17NN
MU17NN
Outdoor unit
precharged
(up to 25ft)
2 lbs 2 oz
2 lbs 14 oz
2 lbs 14 oz
25ft
0
30ft
1
33ft
1
Refrigerant piping length (one way)
40ft
2
45ft
2
49ft
3
3lbs
(2) OPERATION
Function
Cooling
Standard temperature
Maximum temperature
Minimum temperature
Maximum humidity
DB (˚F)
80
95
67
WB (˚F)
67
71
57
Indoor
78%
DB (˚F)
95
115
67
WB (˚F)
Outdoor
Condition
Intake air
temperature
The air coverage range is the value up to the position
where the air speed is 1 ft/sec, when air is blown out
horizontally from the unit properly at the High speed
position.
The coverage range should be used only as a gen-
eral guideline since it varies according to the size of
the room and furniture arranged in the room.
OB192--1.qxp 23/6/97 11:45 PM Page 16