2-6 TIMER operation
2-7 Test run
<Timer function>
AUTO STOP ·········The air conditioner stops after the set time lapses.
AUTO START ········The air conditioner starts after the set time lapses.
AUTO OFF ············Timer is not active.
<How to operate>
1 Push POWER ON/OFF button.
2 Check if or not the current time is correct.
3 Push the or button and select the desired time.
4 Set the timer time using HR and MIN buttons.
ON/OFF TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESETSET CLOCK
SWING
FAN
˚F
PMSTOP
START
AM
COOL
Test run
Measure an impedance between the power supply terminal block on
the outdoor unit and ground with a 500V Megger and check that it is
equal to or greater than 1.0M
".
1 Turn on the main power to the unit.
2 Press the button twice continuously.
(Start this operation from the status of remote controller display
turned off.)
A and current operation mode are displayed.
3 Press the ( ) button to activate COOL mode, then
check whether cool air is blown out from the unit.
4 Press the button and check whether strong air is blown out
from the unit.
5 Press the button and check whether the auto vane operates
properly.
6 Press the ON/OFF button to stop the test run.
Note:
• Point the remote controller towards the indoor unit receiver
while following steps
22
to
66
.
• It is not possible to run the in FAN, DRY or AUTO mode.
MODE
TEST RUN
FAN
VANE
TEST RUN
ON/OFF TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESETSET CLOCK
FAN
TEST
RUN
COOL
A
4
6
3
2
5
OC276-A-2.qxp 03.11.25 9:06 AM Page 36