Mitsubishi Electronics PCA-AGA Air Conditioner User Manual


 
12
7.2. Error Codes indication
ON/OFF
ERROR CODE
If the ON lamp and error code are both flashing: This means that the air conditioner is out of order and operation has been stopped (and cannot resume).
Take note of the indicated unit number and error code, then switch off the power to the air conditioner and call your dealer or servicer.
If you have entered contact number to be called in the event of a problem, the screen displays this number.
(You can set this up under Function Selection of remote controller. For information, refer to section 8.)
Indoor Units Refrig-
erant Address
Error Code
Indoor Unit No.
Alternating Display
ON lamp
(Flashing)
If only the error code is flashing (while the ON lamp remains lit): Operation is continuing, but there may be a problem with the system. In this case, you
should note down the error code and then call your dealer or servicer for advice.
* If you have entered contact number to be called in the event of a problem, push the Check button to display it on the screen. (You can set this up under
Function Selection of remote controller. For information, refer to section 8.)
ON/OFF
˚F
˚F
ERROR CODE
ON/OFF
CALL:XXXX
XXX:XXX
Error Code
8. Function Selection
Function selection of remote controller
The setting of the following remote controller functions can be changed using the remote controller function selection mode. Change the setting when
needed.
Item 1
1.Change Language
(CHANGE
LANGUAGE)
2.Function limit
(FUNCTION
SELECTION)
3.Mode selection
(MODE SELEC-
TION)
4.Display change
(DISP MODE
SETTING)
Item 2
Language setting to display
(1) Operation function limit setting (operation lock) (LOCKING
FUNCTION)
(2) Use of automatic mode setting (SELECT AUTO MODE)
(3) Temperature range limit setting (LIMIT TEMP FUNCTION)
(1) Remote controller main/sub setting (CONTROLLER MAIN/
SUB)
(2) Use of clock setting (CLOCK)
(3) Timer function setting (WEEKLY TIMER)
(4) Contact number setting for error situation (CALL.)
(1) Temperature display °C/°F setting (TEMP MODE °C/°F)
(2) Suction air temperature display setting (ROOM TEMP DISP
SELECT)
(3) Automatic cooling/heating display setting (AUTO MODE
DISP C/H)
Item 3 (Setting content)
Display in multiple languages is possible
Setting the range of operation limit (operation lock)
Setting the use or non-use of automatic operation mode
Setting the temperature adjustable range (maximum, minimum)
Selecting main or sub remote controller
* When two remote controllers are connected to one group, one controller
must be set to sub.
Setting the use or non-use of clock function
Setting the timer type
Contact number display in case of error
Setting the telephone number
Setting the temperature unit (°C or °F) to display
Setting the use or non-use of the display of indoor (suction) air tempera-
ture
Setting the use or non-use of the display of Cooling or Heating display
during operation with automatic mode
7. Other Functions
When the Check button is pressed:
BG79U794H02_en 05.12.22, 2:02 PM12