Mitsubishi Electronics PAR-U02MEDA Fan User Manual


 
– 4 –
The following parts are included in the box.
(1) Field-supplied parts
(2) Required tools
Flat-tip screwdriver (Width: 4-5.5 mm (5/32-7/32 in))
Knife or nipper
Miscellaneous tools
2 Component names and supplied parts
*1 The front cover is already installed on the top case at
factory shipment.
*2 ISO metric screw thread
*3 Remote controller cable is not included.
3 Field-supplied parts/Required tools
Parts name Qty. Notes
Double switch box 1
Not required for direct wall installationThin metal conduit As needed
Locknut and bushing As needed
Cable cover As needed Required for routing remote controller cable along a wall
Putty As needed
Molly anchor As needed
Remote controller cable
(0.3 mm² (AWG 22) 2-core
sheathed cable)
As needed
If the remote controller cable exceeds 10 m (32 ft), use an
electric wire that meets the following specification.
CVVS: 1.25 mm
2
(standard AWG 16) or equivalent
CPEVS: ø1.2 mm (standard AWG 16) or equivalent
Parts name Qty.
Remote controller (front cover) *1 1
Remote controller (top case) *1 1
Remote controller (bottom case) 1
Roundhead cross slot screws M4×30 *2 4
Wood screw 4.1×16 *2
(for direct wall installation)
4
Installation Manual (this manual) 1
Simple Operation Manual 1
CD-ROM
(Installation Manual, Instruction Book)
1
Bottom case
Front cover
Top case
WT06829X02.book Page 4 Wednesday, June 26, 2013 4:03 PM