Mitsubishi Electronics P Air Conditioner User Manual


 
Ceiling Concealed Type Specifications
HEAT PUMP
Type
Indoor Unit
Outdoor Unit
Power Supply [V, Phase, Hz]
PEH-RP200MYA
PUH-P200MYA
20.9
7.92
2.64
D
23.7
7.82
3.03
D
428
1,380
650
70
16.6
50 / 150
53 (at 50Pa)
1,715 x 990 x 840
215
185
56
13.0 - 12.8
50
25.4 / 12.7
50 / 40
0 ~ +43
-12 ~ +15
PEH-RP250MYA
PUH-P250MYA
26.0
9.96
2.61
D
30.5
9.56
3.19
D
428
1,580
650
80
22.2
50 / 150
57 (at 50pa)
1,715 x 990 x 840
220
185
57
16.0 - 15.4
60
28.58 / 12.7
50 / 40
0 ~ +43
-12 ~ +15
Non-Inverter Heat Pump
PEHseries
Cooling
Heating
Indoor
Outdoor
Breaker Size
Ext. Piping
Guaranteed Operating Range
[Outdoor]
Capacity
Total Input
EER
Capacity
Total Input
COP
Dimensions
Weight
Air Volume
External Static Pressure
Sound Level
Dimensions
Weight
Air Volume (High)
Sound Level (High)
Running Current
Diameter
Max. Length / Height
Rated
Rated
EEL Rank
Rated
Rated
EEL Rank
Height
Width
Depth
H x W x D
Cooling - Heating
Gas / Liquid (
Cooling*
Heating
* With the optional air protect guide, the operation at -15
o
C outdoor temperature is possible.
kW
kW
kW
kW
mm
mm
mm
kg
m
3
/min
Pa
dB(A)
mm
kg
m
3
/min
dB(A)
A
A
mm
m
o
C
o
C
400V, 3 phase, 50Hz
PUH-P200/250
73
FIXED SPEED
ACO
Hot Start
Self
Diagnosis
Check!
Lossnay
connection
Group
Control
M-NET
connection
Optional
Auto Restart
Weekly
Timer
Remote Controller
Indoor Unit
Outdoor Unit
Multi
system
74